F-901D10 AccuRipe

 Improve Accuracy & Efficiency In

Ethylene Application Systems

Monitor and control of ripening rooms that specialize in degreening.

EMC---Low-Range

The F-901D10 AccuRipe allows fresh produce operators to monitor and control the levels of C2H4 (Ethylene) in ripening rooms.  With the touch screen mounted in or out of the room, enter a setpoint, then the AccuRipe will automatically regulate ethylene production of our generators or another device, like an ethylene scrubber.

F-901D10 AccuRipe Ethylene Management System Benefits: 

  • Know your ethylene levels anytime from anywhere
  • Have full control of ethylene levels by setpoint and ethylene scrubber or generator modulation
  • Maintain archive of ethylene, RH% and temperature levels (and other conditions with optional sensors)
  • Be alerted to problems by e-mail, text message, or audible alarm


 

Low Range Ethylene Sensor

The system features a Low Range Ethylene Sensor with a setpoint range from 1 – 10 ppm. The sensor is easy to calibrate and replace when needed. An onboard KMnO4 Zero Scrubber will automatically zero the sensor for even better accuracy.

The F-901D10 AccuRipe is great for tomato greenhouses, citrus degreening, potato & onion storage for sprout suppression, and in storage areas for ethylene-sensitive produce.


Remote Access Via Network

Control ethylene output remotely via a network connection. The AccuRipe allows users to view ripening room ethylene, relative humidity, and temperature all at the same time. As an added option, CO2 and O2 levels can be monitored.

Track ethylene progress and adjust output settings in real time with this feature.


 

FEATURES 
Robust alert system, notifications by text, email, or audible
DIY Annual “Maintenance by Mail” with easy to replace sensor pods
Modbus Integration with Catalytic Generators by TCP/IP
Water resistant chassis
Two panels, one for sensors (inside the room) and one for the control panel (in or outside the room)
High precision internal pump
Connection to main power (AC) via external 12V transformer

 

SPECIFICATIONS
Sensor Type Ethylene – Electrochemical
CO2 & O2 sensors available
Range
0 – 10 ppm
Resolution 0.01 ppm
Accuracy 0.3 ppm (absolute), 5% (relative)
Calibration
  • Zero – Weekly (unless using an optional onboard scrubber)
  • Span – 3 months
Sensor Replaceable (by user) Yes, recommended every two years

 